ELKRON : BUS Control Unit MP120-M - (MP3H00211)
MS

EXPANDABLE (UP TO 56 ZONES) CONTROL PANEL
WITH OPTIONAL VOCAL-DIGITAL COMMUNICATOR
AND PC UP/DOWN LOADING
8 zones in the control unit expandable up to 56 zones
Protection degree of the case: IP30/IK02
Dimensions (h x w x d): 318x422x91 mm

 


MS

ELKRON : MP110TG/A - (MP2A00211)
MS

EXPANDABLE (UP TO 56 ZONES) CONTROL PANEL WITH VOCAL-DIGITAL COMMUNICATOR AND PC UP/DOWN LOADING
8 zones in the control unit expandable up to 56 zones: 8 in each input expansion (max 4), 2 in each key reader (max 4), 2 in each remote keypad
Allocable battery (plastic box): 12 V 6 Ah
Switching power supply: 1 A
Dimensions (hxwxd): 345x240x79 mm
With alarm transmission through communicator integrated in the control unit.
Vocal trasmission in option through SV108 unit

MS
MS

ELKRON : Bus controll unit MP120 - (MP0400211)
MS
EXPANDABLE (UP TO 56 ZONES) CONTROL PANEL
WITH OPTIONAL VOCAL-DIGITAL COMMUNICATOR
AND PC UP/DOWN LOADING
8 zones in the control unit expandable up to 56 zones:
8 in each input expansion, 2 in each key reader, 2 in each keypad
8 additional alarm zones + 1 tamper input + 1 auxiliary input in every input expansion that can be either parallel (EP100) , serial (ES100) or wireless (ER20WL)

Dimensions (h x w x d): 345x240x79 mm


MS
MS

ELKRON : C/302 SINGLE ZONE CONTROL UNIT - (SC6000121)
MS
Single Zone central unit, with microprocessor in polycarbonate,
suitable for controlling fire stop doors.
Internally provided with a smoke optical detector and
a heat probe having 60° C intervention threshold.
The unit is capable to manage either up to 15 (optic
or heat) conventional detectors or 2 gas detectors
(BPG/213 model) on a conventional line set to single
permission.

Dimensions (HxLxD): 71x283x113mm
Weight (not including batteries): 700 g

MS
MS

ELKRON : C/54 FOUR ZONE CONTROL UNIT - (SC1800121)
MS
Compact central unit, with microprocessor, suitable for
small size fire and gas systems.
Composed of a red plastic enclosure made in ABS for
wall mounting.
Mechanical key to enable programming functions
and/or commands (silencing, resetting, cutting off,
etc.)
Facility for adding, into the central unit,
an optional module allowing to have either
8 zone relay outputs or a module
allowing to control a solenoid valve (MOD54E).
Number of zones: 4, independent
Max number of detectors per zone: 30 (Smoke, heat, pushbuttons)
Dimensions (HxLxD): 386x269x96 mm
Weight (not including batteries): 2,7 Kg

MS